{"id":101,"date":"2016-04-22T15:17:56","date_gmt":"2016-04-22T15:17:56","guid":{"rendered":"http:\/\/www.lp-equipment.com.my\/2016\/?page_id=101"},"modified":"2016-06-03T05:36:29","modified_gmt":"2016-06-03T05:36:29","slug":"instrumentation-thermometer","status":"publish","type":"page","link":"http:\/\/www.lp-equipment.com.my\/2016\/instrumentation-thermometer\/","title":{"rendered":"Instrumentation &#8211; Thermometer"},"content":{"rendered":"<p>[vc_row bg_type=&#8221;bg_color&#8221; bg_color_value=&#8221;#12548e&#8221;][vc_column][vc_column_text css=&#8221;.vc_custom_1464931421427{margin-left: 50px !important;}&#8221;]<\/p>\n<h1><span style=\"color: #ffffff;\">Instrumentation &#8211; Thermometer<\/span><\/h1>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1464166882834{margin-right: 50px !important;margin-left: 50px !important;}&#8221;][vc_column width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;444&#8243; img_size=&#8221;medium&#8221; onclick=&#8221;link_image&#8221; css_animation=&#8221;bottom-to-top&#8221;][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text css_animation=&#8221;right-to-left&#8221;]T500<br \/>\nBIMETAL THERMOMETERS<\/p>\n<p><strong>All stainless steel \u00a0 | \u00a0\u00a0<\/strong><strong>Short\u00a0 response time \u00a0 | \u00a0\u00a0<\/strong><strong>With or without external\u00a0<\/strong><strong>zero adjustment<\/strong>[\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1464930483360{margin-right: 50px !important;margin-left: 50px !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_column_text css_animation=&#8221;bottom-to-top&#8221; css=&#8221;.vc_custom_1464931708821{margin-left: 50px !important;}&#8221;]<strong>CASE DIAMETER<br \/>\n<\/strong>100,125 and 150 mm<\/p>\n<p><strong>ACCURACY CLASS<br \/>\n<\/strong>1 per EN 13190<\/p>\n<p><strong>TEMPERATURE RANGE<br \/>\n<\/strong>From \u2013 70 to + 500 \u00b0C<\/p>\n<p><strong>AMBIENT TEMPERATURE<br \/>\n<\/strong>From \u2013 20\u00a0 to + 60 \u00b0C<\/p>\n<p><strong>STEM PRESSURE RATING<br \/>\n<\/strong>25 bar (without thermowell)<\/p>\n<p><strong>STANDARD FEATURES\u00a0<\/strong><\/p>\n<p><strong>CASE AND RING<br \/>\n<\/strong>Material: AISI 304 ss<br \/>\nStyle: bayonet ring<br \/>\nProtection class: IP 65\u00a0(EN 60529 \/ IEC 529)<\/p>\n<p><strong>TEMPERATURE ELEMENT<br \/>\n<\/strong>Coiled bimetal<\/p>\n<p><strong>POINTER<br \/>\n<\/strong>Black aluminium<br \/>\nFixed or adjustable<\/p>\n<p><strong>ZERO\u00a0 ADJUSTMENT<\/strong><br \/>\nExternal on the back of case or through adjustable pointer<\/p>\n<p><strong>WINDOW<br \/>\n<\/strong>Glass 4 mm thickness<\/p>\n<p><strong>STEM<br \/>\n<\/strong>AISI 316 ss<\/p>\n<p><strong>STEM DIAMETER<br \/>\n<\/strong>6 \u2013 6.4 \u2013 8 \u2013 10\u00a0 &#8211; 12 mm\u00a0for stem lengths over 1 m\u00a0diameter 8 \u2013 10 \u2013 12 mm only<\/p>\n<p><strong>STEM LENGTHS<br \/>\n<\/strong>Standard lengths from 90 to\u00a0600 mm\u00a0 depending on\u00a0ranges,\u00a0 over 600 mm on\u00a0request[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text css_animation=&#8221;bottom-to-top&#8221;]<strong>CONNECTIONS<br \/>\n<\/strong>Plain, fixed or adjustable<br \/>\nBack, lower and every-angle<br \/>\nEvery-angle connection\u00a0the dial face can be rotated\u00a0360\u00b0 and angled 180\u00b0<\/p>\n<p><strong>THREAD SIZES<br \/>\n<\/strong>\u00bd\u201d BSP or NPT\u2013M standard<br \/>\nSliding on stem or fixed<\/p>\n<p><strong>SERVICE\u00a0 TEMPERATURE<br \/>\n<\/strong>Continuous\u00a0 less\u00a0than 425 \u00b0C<br \/>\nFor continuous service over\u00a0425 \u00b0C, use inert gas type<\/p>\n<p><strong>OVERRANGE LIMITS<br \/>\n<\/strong>Up to 120 \u00b0C : 100%\u00a0 F.S.<br \/>\n160 to 300 \u00b0C : 50% F.S.<br \/>\n400 to 500 \u00b0C : 510 \u00b0C<\/p>\n<p><strong>UNIT OF MEASUREMENT<\/strong><br \/>\nDegree Celsius or Fahrenheith<\/p>\n<p><strong>OPTIONAL EXTRAS<\/strong><br \/>\nCase &amp; stem filled with: glycerine (+15 to+160 \u00b0C) (1)<br \/>\nsilicon oil (-45 to+250 \u00b0C) (1)<br \/>\nfluorolube (-40 to +200\u00b0C) (1)<br \/>\nCase and ring AISI 316 ss<br \/>\nOther thread sizes<br \/>\nDual scale \u00b0C \/ \u00b0F<br \/>\nSafety glass<br \/>\nPlastic window (not for ATEX\u00a0version)<br \/>\nThermowells (see TW data\u00a0Sheet) according to user\u00a0specification.<br \/>\nATEX version (2)<br \/>\n<a href=\"http:\/\/www.lp-equipment.com.my\/2016\/wp-content\/uploads\/2016\/04\/Screen-Shot-2016-06-03-at-1.32.04-PM.jpg\" rel=\"attachment wp-att-447\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-447\" src=\"http:\/\/www.lp-equipment.com.my\/2016\/wp-content\/uploads\/2016\/04\/Screen-Shot-2016-06-03-at-1.32.04-PM.jpg\" alt=\"Screen Shot 2016-06-03 at 1.32.04 PM\" width=\"74\" height=\"59\" \/><\/a><br \/>\nII 2 GD c<\/p>\n<p>Note:<br \/>\n(1) Temperature ranges<br \/>\n(2) ATEX version<br \/>\nII 2 GD c Installation with thermowell only[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text css_animation=&#8221;bottom-to-top&#8221;]<strong>TEMPERATURE RANGES<\/strong><\/p>\n<p>Scale, measuring range, limit of\u00a0error per EN 13 190 class 1<\/p>\n<p><a href=\"http:\/\/www.lp-equipment.com.my\/2016\/wp-content\/uploads\/2016\/04\/Screen-Shot-2016-06-03-at-1.33.21-PM.jpg\" rel=\"attachment wp-att-449\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-449\" src=\"http:\/\/www.lp-equipment.com.my\/2016\/wp-content\/uploads\/2016\/04\/Screen-Shot-2016-06-03-at-1.33.21-PM.jpg\" alt=\"Screen Shot 2016-06-03 at 1.33.21 PM\" width=\"374\" height=\"427\" srcset=\"http:\/\/www.lp-equipment.com.my\/2016\/wp-content\/uploads\/2016\/04\/Screen-Shot-2016-06-03-at-1.33.21-PM.jpg 374w, http:\/\/www.lp-equipment.com.my\/2016\/wp-content\/uploads\/2016\/04\/Screen-Shot-2016-06-03-at-1.33.21-PM-263x300.jpg 263w\" sizes=\"(max-width: 374px) 100vw, 374px\" \/><\/a><\/p>\n<p><em>(1) The measuring range is indicated on dial by two triangular marks. Within this range the stated limit of error is valid according to EN 13190<\/em><\/p>\n<p><strong>STEM LENGTHS TABLE<br \/>\n<\/strong>Minimum stem length mm<\/p>\n<p><a href=\"http:\/\/www.lp-equipment.com.my\/2016\/wp-content\/uploads\/2016\/04\/Screen-Shot-2016-06-03-at-1.33.28-PM.jpg\" rel=\"attachment wp-att-450\"><img loading=\"lazy\" class=\"alignnone size-full wp-image-450\" src=\"http:\/\/www.lp-equipment.com.my\/2016\/wp-content\/uploads\/2016\/04\/Screen-Shot-2016-06-03-at-1.33.28-PM.jpg\" alt=\"Screen Shot 2016-06-03 at 1.33.28 PM\" width=\"334\" height=\"204\" srcset=\"http:\/\/www.lp-equipment.com.my\/2016\/wp-content\/uploads\/2016\/04\/Screen-Shot-2016-06-03-at-1.33.28-PM.jpg 334w, http:\/\/www.lp-equipment.com.my\/2016\/wp-content\/uploads\/2016\/04\/Screen-Shot-2016-06-03-at-1.33.28-PM-300x183.jpg 300w\" sizes=\"(max-width: 334px) 100vw, 334px\" \/><\/a><\/p>\n<p><em><strong>NOTE::<br \/>\n<\/strong><\/em>For shorter length ask our technical dept.<br \/>\nFor compound range, like \u201320 to 60\u00b0C, the stem\u00a0length minimum is the same as 0\/80 \u00b0C, by\u00a0considering the total spam.<\/p>\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row bg_type=&#8221;bg_color&#8221; bg_color_value=&#8221;#12548e&#8221;][vc_column][vc_column_text css=&#8221;.vc_custom_1464931421427{margin-left: 50px !important;}&#8221;] Instrumentation &#8211; Thermometer [\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1464166882834{margin-right: 50px !important;margin-left: 50px !important;}&#8221;][vc_column width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;444&#8243; img_size=&#8221;medium&#8221; onclick=&#8221;link_image&#8221; css_animation=&#8221;bottom-to-top&#8221;][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text css_animation=&#8221;right-to-left&#8221;]T500 BIMETAL THERMOMETERS All stainless steel \u00a0 | \u00a0\u00a0Short\u00a0 response time \u00a0 | \u00a0\u00a0With or without external\u00a0zero adjustment[\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1464930483360{margin-right: 50px !important;margin-left: 50px !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_column_text css_animation=&#8221;bottom-to-top&#8221; css=&#8221;.vc_custom_1464931708821{margin-left: 50px !important;}&#8221;]CASE DIAMETER 100,125 and 150 mm ACCURACY &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"http:\/\/www.lp-equipment.com.my\/2016\/instrumentation-thermometer\/\"> <span class=\"screen-reader-text\">Instrumentation &#8211; Thermometer<\/span> Read More &raquo;<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"http:\/\/www.lp-equipment.com.my\/2016\/wp-json\/wp\/v2\/pages\/101"}],"collection":[{"href":"http:\/\/www.lp-equipment.com.my\/2016\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.lp-equipment.com.my\/2016\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.lp-equipment.com.my\/2016\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.lp-equipment.com.my\/2016\/wp-json\/wp\/v2\/comments?post=101"}],"version-history":[{"count":8,"href":"http:\/\/www.lp-equipment.com.my\/2016\/wp-json\/wp\/v2\/pages\/101\/revisions"}],"predecessor-version":[{"id":453,"href":"http:\/\/www.lp-equipment.com.my\/2016\/wp-json\/wp\/v2\/pages\/101\/revisions\/453"}],"wp:attachment":[{"href":"http:\/\/www.lp-equipment.com.my\/2016\/wp-json\/wp\/v2\/media?parent=101"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}